Corrosion Under Insulation (CUI) Guidelines: Technical Guide for Managing CUI: European Federation of Corrosion (EFC) Series, cartea 55
Editat de Gino De Landtsheeren Limba Engleză Hardback – 19 aug 2020
The guidelines include design of plant and equipment, coatings and the use of thermal spray techniques, types of insulation, cladding/jacketing materials, and protection guards. Corrosion-under-insulation (CUI) refers to the external corrosion of piping and vessels that occurs underneath externally clad/jacketed insulation as a result of the penetration of water. By its very nature CUI tends to remain undetected until the insulation and cladding/jacketing is removed to allow inspection, or when leaks occur. CUI is a common problem shared by the refining, petrochemical, power, industrial, onshore and offshore industries.
- Provides revised and updated technical guidance on managing CUI provided by EFC Working Parties 13 and 15
- Discusses the standard approach to risk based inspection methodology
- Presents the argument that CUI is everywhere, and looks at mitigating actions that can be started from the onset
- Includes a wide array of concepts of corrosion mitigation
Preț: 1011.14 lei
Preț vechi: 1742.15 lei
-42%
Puncte Express: 1517
Carte tipărită la comandă
Livrare economică 01-15 august
Livrare prin curier în România Termenul estimat este afișat lângă disponibilitate.
Transport gratuit pentru acest produs Plată online sau ramburs, în funcție de opțiunile comenzii.
Retur gratuit în 14 zile Comandă securizată și suport în română.
Specificații
ISBN-13: 9780128233320
ISBN-10: 012823332X
Pagini: 180
Ilustrații: 100 illustrations (40 in full color)
Dimensiuni: 152 x 229 mm
Greutate: 0.41 kg
Ediția:3
Editura: ELSEVIER SCIENCE
Seria European Federation of Corrosion (EFC) Series
ISBN-10: 012823332X
Pagini: 180
Ilustrații: 100 illustrations (40 in full color)
Dimensiuni: 152 x 229 mm
Greutate: 0.41 kg
Ediția:3
Editura: ELSEVIER SCIENCE
Seria European Federation of Corrosion (EFC) Series
Cuprins
1. Introduction
2. Economic consideration
3. Ownership and responsibility
4. The risk-based inspection methodology for corrosion-under-insulation
5. Inspection activities and strategy
6. Non-destructive examination and testing screening techniques for corrosion-under-insulation
7. Recommended best practice to mitigate corrosion-under-insulation
8. Design for the prevention of corrosion-under-insulation
Appendix
A. Cost-economic evaluation
B. Quality assurance
C. Additional guidelines on the implementation of corrosion-under-insulation best practice
D. Coatings
E. Application of thermally sprayed aluminium
F. Insulation material types and forms
G. Cladding and jacketing materials
H. Use of protection guards
I. Non-destructive examination and testing techniques
2. Economic consideration
3. Ownership and responsibility
4. The risk-based inspection methodology for corrosion-under-insulation
5. Inspection activities and strategy
6. Non-destructive examination and testing screening techniques for corrosion-under-insulation
7. Recommended best practice to mitigate corrosion-under-insulation
8. Design for the prevention of corrosion-under-insulation
Appendix
A. Cost-economic evaluation
B. Quality assurance
C. Additional guidelines on the implementation of corrosion-under-insulation best practice
D. Coatings
E. Application of thermally sprayed aluminium
F. Insulation material types and forms
G. Cladding and jacketing materials
H. Use of protection guards
I. Non-destructive examination and testing techniques